Showing results: 106 - 120 of 158 items found.
-
8004e -
Sealevel Systems, Inc.
The 8004e PCI Express digital I/O interface provides 16 optically isolated inputs and 16 Reed relay outputs. The isolated inputs protect the PC and other sensitive equipment from the voltage spikes and ground loop currents that are common to industrial environments. The outputs provide high quality, long-life, dry contact switch closures suitable for low-current applications.
-
8004He -
Sealevel Systems, Inc.
The 8004He PCI Express digital I/O interface provides 16 optically isolated inputs and 16 Reed relay outputs. The isolated inputs protect the PC and other sensitive equipment from the voltage spikes and ground loop currents that are common to industrial environments. The outputs provide high quality, long-life, dry contact switch closures suitable for low-current applications.
-
DA1 -
North Atlantic Industries
The DA1 module features 12 independent D/A output channels with a full-scale range of ±10 VDC at ± 25 mA (max). The DA1 provides either voltage or current control loop modes that are programmable for the particular application. The DA1 module also offers external trigger/synchronization signal (RS422/485) capability, which provides/accepts a trigger signal to/from other module(s).
-
ProDAQ 3510 -
Bustec Ltd.
The ProDAQ 3510 DAC function card is a ProDAQ high-density card that fits into ProDAQ VXIbus motherboards and LXI function card carriers. This high-density card contains 16 independent, 16-bit DAC channels, and each channel is equipped with its own DAC. The ProDAQ 3510 DAC function card is specially designed for DC, low-frequency, and current loop applications.
-
4014 -
Red Phase Instruments Australia Pty Ltd.
The Model 4014 integrates four ammeters for the direct and simultaneous reading of C.T. secondaries up to 10A during the setting up or checking of protection systems while they are in service with normal 50/60Hz primary currents flowing. The two terminals of each channel of the Model 4014 are connected in series with the C.T. secondary with all other equipment in the loop or directly across the C.T. secondary.
-
6280 TB -
Standard Electric Works Co., Ltd
● Wide range of operating voltage from AC 210V/50Hz to 250V/50Hz.● For checking AC voltage.● For checking a RCD tester's test current & time in mA(ms).● For checking a loop tester.● For wiring check (Phase, Neutral, Earth).● For checking continuity.● For checking insulation (The maximum is 1.2kV).● For checking UK16th edition.● Safety standard: EN 61010-1 / EN 61326-1
-
HL-200 -
Neutronics Manufacturing Co.
Measuring the line loop contact resistance by bridges is not the ideal method as the test current is only a few milli amperes. Thus the value is not the true value of the contact resistance. Model HL- 200 is a direct reading tester, and uses a test current of 200A DC, resulting in true value and accurate measurements. Model HL- 200 adopts digital circuit technique and is used for measuring contact resistance of switch control equipment at test current of 200A DC. The measurements are accurate as the test is highly stable. HL- 200 is a new, fully automatic micro controlled tester that measures contact resistance at 200A DC with built in printer.
-
PRODIGIT Electronics Co, Ltd.
*Easy to see now test progress*Can cycle test*Provide Charge, Discharge, Suspend, FOR, LOOP Mode Select*When Charging, set the stop current to stop charging when fully charged so as to avoid overcharging that will damage the battery. When Discharge, set the stop voltage to stop discharge when discharging to lowest so as to avoid over-discharging that will damage the battery.
-
Macintyre Electronic Design Associa
he MEDA turnkey closed loop magnetic field sources cancel the local ambient field as well as generate accurate and uniform magnetic fields in a control volume. The sources use Helmholtz coils driven by control currents to produce stable magnetic fields from 1 nT to 100,000 nT. The accuracy of the field in the control volume is better than 0.05% of the setting.
-
Neutronics Manufacturing Co.
Introduction: Measuring the line loop contact resistance by bridges is not the ideal method as the test current is only a few milli amperes. Thus the value is not the true value of the contact resistance. Model HL- 100 is a direct reading tester, and uses a test current of 100A DC, resulting in true v alue and accur ate measurements. Model HL- 100 adopts digital circuit technique and is used for measuring contact resistance of switch control equipments at test current of 100A DC. The measurements are accurate as the test is highly stable.HL- 100 is a new, fully automatic micro controlled tester that measures contact resistance at 100A DC with built in printer. The advantages of HL-100
-
785046-01 -
NI
8-Channel C Series Current Output Module - The NI‑9266 is ideal for interfacing and controlling industrial current-driven actuators. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9266 includes channel‑to‑earth ground isolation for safety and noise immunity.
-
785047-02 -
NI
8-Channel C Series Current Output Module - The NI‑9266 is ideal for interfacing and controlling industrial current-driven actuators. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9266 includes channel‑to‑earth ground isolation for safety and noise immunity.
-
785047-01 -
NI
8-Channel C Series Current Output Module - The NI‑9266 is ideal for interfacing and controlling industrial current-driven actuators. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9266 includes channel‑to‑earth ground isolation for safety and noise immunity.
-
9841 -
PRODIGIT Electronics Co, Ltd.
*Easy user interface*Measure Voltage, Current, Power, KWH, AH, Temperature, Reference Voltage*Accuracy Measure Time*Easy to see now test progress*Can cycle test*Provide Charge, Discharge, Suspend, FOR, LOOP Mode Select*When Charging, set the stop current to stop charging when fully charged so as to avoid overcharging that will damage the battery. When Discharge, set the stop voltage to stop discharge when discharging to lowest so as to avoid over-discharging that will damage the battery. *The test result will be stored to ACCESS data
-
MEWOI Electronics Co.,ltd
High Voltage Current Transformation Ratio Tester breaks traditional structure, specially designed for high and low voltage first and secondary loop current, variable ratio, and current leakage test; apply the latest CT technology and mask digital integration technology, composed of special high-voltage clamp, low voltage clamp, host, high voltage insulation rod and monitoring software, etc; its wireless transmission test data can penetrate multiple building obstacles with a straight-line distance of 30 meters.